Compare

Analog input cards

We offer several product lines in the range of analog inputs:

1. EP series - measuring cards for three-phase voltage and current measurement, alternatively with a fourth input for direct I0 measurement, for U0 measurement or additional voltage measurements. In addition to phase measurements, the cards also calculate phase to phase voltages, P, Q, S, f, cos φ, THD. If I0 and U0 are not measured directly, the card can calculate them from three-phase measurements. The cards indicate faults on electrical voltage lines according to ANSI standards and can work as protection relays in cooperation with digital I/O cards. Depending on the type of application, the overload capability of the inputs can also be selected, so that data during the fault on the line are available.

2. AI series - measuring cards for industrial standards measuring, usually 20 mA or 10 V,
                   - special fast measuring cards (up to 40 MS/s),
                   - temperature measurement.

3. EQ series - cards for measuring the power quality and energy (they were originally part of the AI series).

RTU7M AI-12I/5/6-I
221320550034
The goods are made to order
4x3xAI, indirect, +/-5mA DC, 5mA AC, overloadability permanently 1,2xIn, isolated
RTU7M AI-12ID/20/24-I
221320550036
The goods are made to order
Indirect card for analog measurement, inputs 12 x I, +/-20 mA DC, 0-20 mA DC, 4-20 mA DC, permanent overloadability 1.2 x In, isolated from backplane
221320550045
The goods are made to order
Indirect card for analog measurement, inputs 3xI/20/20 mA, +/-20mA DC, 0-20mA DC, 4-20mA DC, 16-bit resolution, isolated from bus and all inputs from each other.
RTU7M AI-3UA/230/300-3IA/5A/7.5A-I
221320550300
The goods are made to order
Indirect power quality metering card in class S. Inputs 3xU/230/300 V, 3xI/5/7.5A.
RTU7M AI-4UF/1.28-AI
221320550210
The goods are made to order
Indirect fast analog input card (1,28Vpeak, 75 Ohm, 40MS/s, 10Hz - 20MHz)
RTU7M AI-6ID/20/20-AI
221320550046
The goods are made to order
Indirect card for analog measurement, inputs 6xI/20/20 mA, +/-20mA DC, 0-20mA DC, 4-20mA DC, 16bit resolution, isolated from bus and all inputs each other, usage with DC transducers
221320550037
The goods are made to order
Indirect card for analog measurement, inputs 6xU/10V/12V, 6xI/20mA/24mA, isolated.
221320552000
The goods are made to order
Card for temperature measurement, 8 independent inputs for PT100, PT1000, Ni120, or thermocouple K-Type.
RTU7M EP-3U/100/120-3I/1.66/6.64-I
221320550050
The goods are made to order
Indirect card for analog measurement, inputs 3xU/100/120 V, 3xI/1,66/6,64 mA, isolated
RTU7M EP-3U/100/120-3I/1-5A/10A-I
221320550063
The goods are made to order
Indirect card for analog measurement, inputs 3xU/100/120V, 3xI/1-5A/10A, isolated.
RTU7M EP-3U/100/120-3I/20/200-I
221320550052
The goods are made to order
Indirect card for analog measurement, inputs 3xU/100/120V, 3xI/20/200mA, isolated
RTU7M EP-3U/100/120-4U/0.225/4.5/24K-I
221320550380
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/100/120 V, 4xU/0.225/4.5 V, isolated. Designed for application Zelisko current sensors.
RTU7M EP-3U/2.2/2.64-1U/100/120-4I/5/150-I-DI08-UM-DO04-U
221320550110
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/2.2/2.64 V, 1xU/100/120 V, 4xI/5/150 mA, isolated, 8xDI/24 VDC, 4xDO. Designed for application of recloser of brand GVR (with capacitive sensors and voltage converter 10kV/1V).
RTU7M EP-3U/230/295-3I/1-5A/10A-I
221320550064
The goods are made to order
Indirect card for analog measurement, inputs 3xU/230/295V, 3xI/1-5A/10A, isolated.
RTU7M EP-3U/230/295-3I/20/200-I
221320550062
The goods are made to order
Indirect card for analog measurement, inputs 3xU/230/295V, 3xI/20/200mA, isolated
RTU7M EP-3U/25/30-1U/100/120-4I/5/150-I-DI08-UM-DO04-U
221320550094
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/25/30V, 1xU/100/120V, 4xI/5/150mA, isolated, 8xDI/24VDC, 4xDO. Designed for Recloser GVR with resistive sensors of voltage. Measurement up to 30xIn and 1,2 Un.
RTU7M EP-3U/25/30-1U/100/120-4U/2/60-I-DI08-UM-DO04-U
221320550092
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/25/30V, 1xU/100/120V, 4xU/2/60V, isolated, 8xDI/24VDC, 4xDO. Designed for sensors FSI36 (measurement up to 30xIn) and FSU36 (measurement up to 1,2xUn), this card is a substitute for units SADS
RTU7M EP-3U/3.25/3.9-1U/100/120-1I/1A/2A-3I/1A/20A-I-DI08-UM-DO04-U
221320550112
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.25/3.9 V, 1xU/100/120 V, 1xI/1A/2A, 3xI/1A/20A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of reclosers Siemens with voltage sensors RITZ GSR 38.
RTU7M EP-3U/3.575/4.29/1M-3I/20/200-I
221320550061
The goods are made to order
Indirect card for analog measurement, inputs 3xU/3,575/4,29 V (input impedance 1 MOhm), 3xI/20/200 mA, isolated
RTU7M EP-3U/3.575/4.29/M2-1U/100/120-4U/0.225/4.5/24K-I-DI08-UM-DO04-U
221320550208
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.575/4.29 V, 1xU/100/120 V, 4xU/0.225/4.5 V, isolated, 8xDI/24 VDC, 4xDO. Designed for application Zelisko sensors.
RTU7M EP-3U/3.575/4.29/M2-4U/0.225/4.5/24K-I
221320550310
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.575/4.29 V, 4xU/0.225/4.5 V, isolated. Designed for application Zelisko sensors.
RTU7M EP-3U/4.4/5.28-1U/100/120-3U/0.88/17.6-1U/0.176/0.352-I-DI08-UM-DO04-U
221320550620
The goods are made to order
Indirect card for analog measurement, inputs 8xU for sensors in Tavrida reclosers with Rogowski coils, isolated.
RTU7M EP-3UA/0.75/3-3I/1/20A-I
221320550330
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/0.75/3V, 3xI/1A/20A, isolated. Voltage inputs are designed for connection to VPIS V3 VO (VPI626x8).
RTU7M EP-3UA/2.5/3-1U/100/120-4I/1A/30A-I-DI08-UM-DO04-U
221320550120
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/2.5/3 V (only AC measurement, usage with capacitive sensors VSO 25), 1xU/100/120 V, 4xI/1/30 A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of load disconnector / load break switch /
221320550350
The goods are made to order
Nepřímá karta pro analogová měření, vstupy 3xU/25/30V, 1xI/1A/2A, 3xI/1A/20A, izolovaná. Napěťové vstupy uzpůsobené pro přímé připojení k detektorům napětí Capdis-S1+/Capdis-S2+ a obdobným.
RTU7M EP-3UA/3.25/3.9-1U/100/120-1I/1A/2A-3I/1A/20A-I-DI08-UM-DO04-U
221320550125
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.25/3.9 V, 1xU/100/120 V, 1xI/1A/2A, 3xI/1A/20A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of reclosers Tavrida with senzors VSO25.1 up to capacity 35 pF on 22 kV networks.
RTU7M EP-3UA/4/4.8-1U/100/120-1I/1A/2A-3I/1A/20A-I
221320550059
The goods are made to order
Indirect card for analog measurement, inputs 3xU/4/4.8V, 1xU/100/120V, 1xI/1A/2A, 3xI/1A/20A, isolated
RTU7M EP-3UA/4/4.8-1U/100/120-1I/1A/2A-3I/1A/20A-I-DI08-UM-DO04-U
221320550130
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/4/4.8 V (only AC measurement, usage with capacitive sensors Tavrida, VSO 25, VSO 25.1, CVSO 25), 1xU/100/120 V, 1xI/1/2 A, 3xI/1/20 A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of
RTU7M EP-4U/100/120-1I/1A/10A-3I/5A/150A-I-DI08-UM-DO04-U
221320550088
The goods are made to order
Indirect card for analog measurement with function of protection, inputs 4xU/100/120 V, 1xI/1/10 A, 3xI/5/150 A, 8xDI/24 VDC, 4xDO, isolated
RTU7M EP-4U/100/120-4I/1-5A/10A-I
221320550069
The goods are made to order
Indirect card for analog measurement, inputs 4xU/100/120 V, 4xI/1-5 A/10 A, isolated.