Compare

Analog input cards

We offer several product lines in the range of analog inputs:

1. EP series - measuring cards for three-phase voltage and current measurement, alternatively with a fourth input for direct I0 measurement, for U0 measurement or additional voltage measurements. In addition to phase measurements, the cards also calculate phase to phase voltages, P, Q, S, f, cos φ, THD. If I0 and U0 are not measured directly, the card can calculate them from three-phase measurements. The cards indicate faults on electrical voltage lines according to ANSI standards and can work as protection relays in cooperation with digital I/O cards. Depending on the type of application, the overload capability of the inputs can also be selected, so that data during the fault on the line are available.

2. AI series - measuring cards for industrial standards measuring, usually 20 mA or 10 V,
                   - special fast measuring cards (up to 40 MS/s),
                   - temperature measurement.

3. EQ series - cards for measuring the power quality and energy (they were originally part of the AI series).

RTU7M AI-4UF/1.28-AI
221320550210
The goods are made to order
Indirect fast analog input card (1,28Vpeak, 75 Ohm, 40MS/s, 10Hz - 20MHz)
221320550306
The goods are made to order
Indirect power quality metering card in class A. Inputs 3 x 230 V AC, 3 x 5 A.
RTU7M EP-4U/100/120-1I/1A/10A-3I/5A/150A-I-DI08-UM-DO04-U
221320550088
The goods are made to order
Indirect card for analog measurement with function of protection, inputs 4xU/100/120 V, 1xI/1/10 A, 3xI/5/150 A, 8xDI/24 VDC, 4xDO, isolated
RTU7M EP-4U/100/120-4I/20/200-I-DI08-UM-DO04-U
221320550070
The goods are made to order
Indirect card for analog measurement with function of protection, inputs 4xU/100/120V, 4xI/20/200mA, 8xDI/24VDC, 4xDO, isolated
RTU7M EP-3U/25/30-1U/100/120-4U/2/60-I-DI08-UM-DO04-U
221320550092
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/25/30V, 1xU/100/120V, 4xU/2/60V, isolated, 8xDI/24VDC, 4xDO. Designed for sensors FSI36 (measurement up to 30xIn) and FSU36 (measurement up to 1,2xUn), this card is a substitute for units SADS
RTU7M EP-3U/2.2/2.64-1U/100/120-4I/5/150-I-DI08-UM-DO04-U
221320550110
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/2.2/2.64 V, 1xU/100/120 V, 4xI/5/150 mA, isolated, 8xDI/24 VDC, 4xDO. Designed for application of recloser of brand GVR (with capacitive sensors and voltage converter 10kV/1V).
RTU7M EP-3UA/2.5/3-1U/100/120-4I/1A/30A-I-DI08-UM-DO04-U
221320550120
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/2.5/3 V (only AC measurement, usage with capacitive sensors VSO 25), 1xU/100/120 V, 4xI/1/30 A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of load disconnector / load break switch /
RTU7M EP-4U/230/295-4I/1A/30A-I-DI08-UM-DO04-U
221320550086
The goods are made to order
Indirect card for analog measurement with function of protection, inputs 4xU/230/295 V, 4xI/1/30 A, 8xDI/24 VDC, 4xDO, isolated.
RTU7M EP-4U/100/120-4I/1A/30A-I-DI08-UM-DO04-U
221320550084
The goods are made to order
Indirect card for analog measurement with function of protection, inputs 4xU/100/120 V, 4xI/1/30 A, 8xDI/24 VDC, 4xDO, isolated.
RTU7M EP-3U/25/30-1U/100/120-4I/5/150-I-DI08-UM-DO04-U
221320550094
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/25/30V, 1xU/100/120V, 4xI/5/150mA, isolated, 8xDI/24VDC, 4xDO. Designed for Recloser GVR with resistive sensors of voltage. Measurement up to 30xIn and 1,2 Un.
RTU7M EP-3U/3.25/3.9-1U/100/120-1I/1A/2A-3I/1A/20A-I-DI08-UM-DO04-U
221320550112
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.25/3.9 V, 1xU/100/120 V, 1xI/1A/2A, 3xI/1A/20A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of reclosers Siemens with voltage sensors RITZ GSR 38.
RTU7M EP-3UA/3.25/3.9-1U/100/120-1I/1A/2A-3I/1A/20A-I-DI08-UM-DO04-U
221320550125
The goods are made to order
Indirect card for analog combined measurement, inputs 3xU/3.25/3.9 V, 1xU/100/120 V, 1xI/1A/2A, 3xI/1A/20A, isolated, 8xDI/24 VDC, 4xDO. Designed for application of reclosers Tavrida with senzors VSO25.1 up to capacity 35 pF on 22 kV networks.
Load more
Loading...
Login to the newsletter was successful.
Something is wrong, contact us.

Košík obsahuje nepovolené položky

Košík je prázdný

Show basket

The article was added to comparison

Please wait...
Unable to complete your order, please try again later
Chyba při vložení do košíku
Nepovolená kombinace - košík obsahuje dárek z věrnostního programu, který je možné uplatnit pouze v samostatné objednávce.
Chyba při odebrání z košíku
Dárek lze uplatnit pouze v samostatné objednávce.
Dárek lze uplatnit pouze s nákupem alespoň jedné položky.
Máte blokované čerpání bodů
Error adding gift to cart
Pro vložení do košíku nemáte dostateční počet bodů
Dárek není skladem

Hlídání zboží bylo úspešně nastaveno. Budeme vás informovat emailem.

Požadavek nemůže být odeslán. Zkuste to znovu později